bis zu 15kVA im Einzel und 45kVA im Parallelbetrieb
- Rated power: 9kVA, 12kVA, 15kVA
- Rated current: 87Arms, 96Arms, 105Arms
- Voltage range: 30Vrms~350Vrms
- Frequency range: 30Hz~100Hz
- Crest factor range: 1.414~3.000
- Power factor range: 0.100~1.000 (lead/lag)
- 3U height with up to 15kVA high power density
- Intuitive Touch Panel Interface
- High precision, equivalent to linear load levels
- Selectable single-phase and three-phase load mode
- Accept reverse rated apparent power with 89% efficiency regenerative conversion to grid
- Rectified load mode
- Leading/lagging current load mode
- Current source mode
- Stand-By fast response functionality
- Inductive/capacitive load simulation function
- Positive/negative half-cycle load function
- Configurable start/end loading current phase angles
- Configurable current load upper limit
- Universal AC Input Range
- Parallelable (by three-phase mode) for higher power output
- Standard remote interfaces: USB, LAN, Optional remote interfaces: GPIB, CAN
- Suitable for EVSE, Off-Grid PV inverter, and UPS product test applications
Das PRodukt ist in folgender Kategorie zu finden:
AC-DC LastProduktgruppen
- Messtechnik
- Prüftechnik
- Labor
-
EMV+CE
- Automotive - Elektrische Störungen
- Automotive - Spannungsvariationen
- Automotive - Batteriesimulatoren
- Elektrostatische Entladung (ESD)
- Harmonische & Flicker
- Ring Wave / Damped Oscillatory
- Spannungseinbrüche, -unterbrechungen, und -schwankungen
- Transienten (Burst, Surge)
- Magnetfeld
- Leitungsgebundene Störfestigkeit HF/NF
- EMV- MESSEMPFÄNGER
- EMV- Software
- Antennas + Tripods
- Absorber- Cabins and Rooms
- GTEM-, TEM- Cells, Stripline
- E- Mobility
- Verstärker
- CDN, LISN, Probes, Clamps
- EMC / RF- Accessories, TEKBOX
- VSWR- Brücken
- AC/DC Quellen-Lasten
- ESD-Ausrüstung
- CE-Prüfung
- Vorführgeräte
- Zubehör
- Aktionsprodukte